X77 95% (HPLC) Research Chemical - High Purity & Quality, CAS Number 2455518-33-7

REF #: 3199400
Procurenet
Short description
  • X77 95% (HPLC) Research Chemical
  • CAS Number: 2455518-33-7
  • Synonyms: (u00b1R)-N-Cyclohexyl-(u00b1)-[[4-(1,1-dimethylethyl)phenyl](1H-imidazol-5-ylcarbonyl)amino]-3-pyridineacetamide
  • Highly pure research chemical with 95% concentration (HPLC)
  • Used for scientific research and analysis
  • Explore related peer-reviewed papers, technical documents, and similar products
  • Find -SML3157 MSDS for safety information
$0
Quantity :
  • Procurenet Team Tshim Sha Tsui
    Hong Kong Hong Kong 3 years
Delivery options
  • 7 Days Return Back Policy
  • 2 Days Cancellation Policy
  • Ship Only
Description

X77 95% (HPLC) Research Chemical

Product Number: X77

CAS Number: 2455518-33-7

Synonyms: (u00b1R)-N-Cyclohexyl-(u00b1)-[[4-(1,1-dimethylethyl)phenyl](1H-imidazol-5-ylcarbonyl)amino]-3-pyridineacetamide

Description

X77 95% (HPLC) is a high-quality research chemical commonly used in scientific laboratories for various applications. The compound has a purity of 95% as determined by High-Performance Liquid Chromatography (HPLC) analysis. It is carefully manufactured to meet the specific requirements of researchers and professionals in the field.

Key Features:

  • Purity: X77 has a purity of 95% (HPLC). The high purity ensures reliable and accurate results in various applications.
  • Quality Control: The product undergoes rigorous quality control measures to ensure consistent quality and performance.
  • Synonyms: X77 is also known as (u00b1R)-N-Cyclohexyl-(u00b1)-[[4-(1,1-dimethylethyl)phenyl](1H-imidazol-5-ylcarbonyl)amino]-3-pyridineacetamide.
  • CAS Number: The CAS Number of X77 is 2455518-33-7, which serves as a unique identifier for the compound.

Applications

X77 95% (HPLC) can be used in various research and industrial applications, including:

  • Chemical synthesis: X77 can be used as a key building block in the synthesis of complex organic compounds for pharmaceutical, agrochemical, and material science applications.
  • Biomedical research: The compound has potential applications in biomedical research, including drug discovery, target identification, and protein binding studies.
  • Pharmacology: X77 can be utilized for in vitro pharmacological screenings to assess the activity and potency of various compounds.
  • Pharmaceutical analysis: The compound can be used as a reference standard or analytical tool in the analysis of pharmaceutical formulations and drug stability studies.
  • Environmental analysis: X77 can be employed for environmental analysis, such as the detection and quantification of pollutants and contaminants.

Handling and Storage

Proper handling and storage of X77 95% (HPLC) are essential to maintain its quality and stability. The following precautions should be taken:

  • Store the compound in a cool, dry place away from direct sunlight.
  • Ensure that the container is tightly closed when not in use to prevent moisture absorption.
  • Handle X77 with appropriate protective equipment, such as gloves and safety goggles, to avoid direct contact with the skin, eyes, and mucous membranes.
  • Keep X77 away from incompatible materials and sources of ignition.

Technical Information

Technical information about X77 95% (HPLC) is provided below:

  • Molecular Formula: C23H28N6O2
  • Molecular Weight: 424.52 g/mol
  • Appearance: Off-white to light yellow solid
  • Stability: X77 is stable under recommended storage conditions. However, it may undergo degradation under certain extreme conditions. Please refer to the MSDS for more information.
  • Solubility: X77 is soluble in common organic solvents such as methanol, ethanol, and dimethyl sulfoxide (DMSO).
  • Storage Temperature: Store X77 at -20u00b0C. Avoid repeated freeze-thaw cycles.
  • Shipping Condition: X77 is shipped at room temperature.

Precautions

As with all chemicals, X77 95% (HPLC) should be handled with care. Some general precautions to be followed include:

  • Avoid ingestion, inhalation, or direct contact with skin, eyes, and mucous membranes. In case of contact, rinse immediately with plenty of water and seek medical advice.
  • Use X77 only in well-ventilated areas or under a fume hood to prevent the accumulation of vapors.
  • Wear appropriate personal protective equipment, including gloves, safety goggles, and lab coat, when handling the compound.
  • Dispose of X77 and its containers in accordance with local regulations.

For detailed information on safety, handling, and storage, please refer to the Material Safety Data Sheet (MSDS) available for X77 (find -SML3157 MSDS). Consult the MSDS for information on first aid measures, handling and storage practices, and potential hazards associated with the compound.

Ordering Information

For pricing, availability, and ordering information of X77 95% (HPLC), please contact our sales department or visit our website. Our team of experts will be happy to assist you with any inquiries you may have.

All categories
Filters